The modular XL-T and XL-R series of MultiCentres can be configured to meet your requirements. Choose 4-axis for polar rotation only, and 5-axis if azimuthal rotation is also required. In addition, heating and cooling can also be specified. If sample heating is required, resistive heating to 900°C and e-beam heating to 1200°C options are available. If sample cooling is required, LN2 cooling to <-150°C and LHe to <30K options can be included.

The options are summarised in the section below.

Read more

Key features

  • Choice of X,Y, Z motion and polar and azimuthal rotations
  • Resistive and e-beam heating options
  • Heating to 1200oC
  • LN2 and LHe cooling options
  • Cooling to 30K
Show me more key features

Configuration options

Choice of 4 or 5 axis configurations

Both the XL-T and XL-R range of multicentres are available in 4 or 5 axis configurations to suit the application requirements. 

4 axis (X,Y,Z,R1) 5 axis (X,Y,Z,R1,R2)
The 4 axis option provides a range of X, Y and Z movements with magnetically coupled rotary drive providing the polar (primary) rotation. The 5 axis option provides a range of X, Y and Z movements with magnetically coupled rotary drives providing both the polar (primary) rotation and azimuthal (secondary) rotation.

 

Choice of industry standard sample holders

Both the XL-T and XL-R range of multicentres can be configured to accept industry standard sample holders (detailed below).

Puck Flag Esca Stub
25.4mm (d) x 10.9mm (h) 15mm (l) x 19mm (w) 10mm (d) x 17mm (h)

Choice of resistive and e-beam heating options

Both the XL-T and XL-R range of multicentres can provide resistive sample heating to 900oC or e-beam sample heating to 1,200oC (typical values).

Resistive heating to 900oC E-beam heating to 1,200oC
Robust self-supporting Ta foil heater, for minimum outgassing and large ratio of heated to open surface area ensuring heater longevity. The filament is also Yttria coated to provide additional robustness in oxidising atmospheres and for protection in the event of an accidental vent. Note: heating limited to 600°C with LHe option. For higher temperature requirements the e-beam heating option achieves sample temperatures up to 1200°C. To upgrade to e-beam heating simply requires a change of power supply unit.
Click graph to view large version of typical heating performance.

Choice of LN2 and LHe cooling options

Both the XL-T and XL-R range of multicentres can provide LN2 sample cooling to -170oC or LHe sample cooling to 30K (-243oC) (typical values).

LN2 cooling to -170oC LHe cooling to 30K (-243oC)
Innovative LN2 cooling module provides sample cooling down to <-150°C with continuous azimuthal rotation and temperature measurement. Typically the LN2 cooling can achieve sample temperatures to <-170°C. The LN2 circuit is routed through the hollow shaft with the coils inside the service collar to minimise the swept volume of the stage head.
 
Based on UHV Design’s own continuous flow cryostat, cryogenic temperatures below 30K can be achieved in less than one hour.
Click to view large version









 
Click to view large version
Click to view large version

 

Advanced stage options

Thanks to the unique unlcuttered design of the stage it is possible to add the following advanced stage options:

Single flag-style parking position  Two level parking positions
5-axis flag-style heat / cool stage with the following additional features:

(a) Single flag-style sample parking position which can loaded from either side by a wobble stick, is electrically floating for biasing and sample current measurement, and can be cooled 

(b) Toggle mechanism which can be operated by a wobble stick to disengage the thermocouple from the back of the sample plate. Normally this functionality is accomplished by the forks on the magnetic transfer arm which engage in the end of the manipulator and disengage the thermocouple in the process 
4-axis flag-style heat / cool stage with a 2 level parking stage (c), both electrically floating and coolable into which can be loaded from either side:

- 2 standard flag samples,
- or two direct current heating flag samples, or 
- a mixture thereof
- a special flag-style sample plate with a QMB (Quartz Micro-balance) FTM (Film Thickness Monitor) mounted on it, or
-a special flag-style sample plate with an e-beam heater module which when loaded into the lower position can be used to heat a standard flag-style sample in the upper level to 1200°C

 

Flag mounted STM tip holder parking stage Large flag-style parking position
5-axis flag-style heat / cool stage showing  a custom parking position for the conditioning of flag mounted STM tips (d) 4-axis flag-style heat / cool stage  - showing an additional parking position for a large (30x30mm) flag-style sample plate (e), which is also electrically isolated for biasing and sample current measurement, and can be cooled